ENTEL DT922, DT982 and DT952 radios — ATEX IIC

ENTEL DT922 (VHF), DT982 (UHF) and DT952 (PMR446) are top-group IIC explosion-proof radios without a display. 16 channels, voice announcement, glove-friendly operation — for staff in areas with hydrogen, acetylene and any group II gas.

from $899EXW Hong Kong, excl. VAT · CPT to the buyer's airport — quoted per order

Specifications

ATEX markingII 2G Ex ib IIC T4 Gb
TR CU 012/2011 marking1Ex ib IIC T4 Gb X
Mining execution (TR CU)PB Ex ib I Mb X · PO Ex ia I Ma X
FrequencyDT922 — VHF 136–174 MHz · DT982 — UHF 400–470 MHz · DT982U — UHF 450–520 MHz · DT952 — PMR446
ModesDT922 / DT982 — DMR Tier II and analogue · DT952 — DMR Tier I and analogue
Channels16, voice channel announcement
RF outputlimited by group IIC requirements (2 W EIRP per manufacturer data); DT952 — 0.5 W
BatteryCNB950EV2, Li-ion 1800 mAh
ProtectionIP68, MIL-STD-810 C/D/E/F
Size and weight138 × 60 × 38 mm, 435 g
EAEU certificate RU C-PH.HA65.B.02659/25 (TR CU 012/2011), valid until 10 July 2030. The mining marking PB Ex ib I Mb X / PO Ex ia I Ma X applies with the CNB950EV2 battery, CHPD/DT9, CHPHS/DT9 or CHPHD/DT9 headsets, CMP/DT9 speaker microphone and CLC/DT2 or CLC/DT5 leather case. Certificate copies are provided on request or with purchase.

Applications

Hydrogen, chlorine and petrochemical plants, gas processing — for staff who need simple communication without a screen.

The DT952 works in licence-free PMR446: suitable where the site has no assigned frequencies. Check that PMR446 is permitted in the country of use. The DT922 and DT982 work on the site’s own frequencies.

Safety features

emergency button; Lone Worker and Man Down are optional.

In the box

radio, 1800 mAh Li-ion battery, rapid charger, antenna, belt clip, quick start guide.

Conditions for safe use (X marking)

  • use only batteries, chargers and accessories listed in the certificate;
  • do not charge the battery in a hazardous area;
  • operate in the CLC/DT2 or CLC/DT5 protective leather case;
  • if the housing or antenna is damaged, remove the radio from the hazardous area.

Request a quote for DT982

Quotation and invoice in USD within 1 business day. Certificate copies on request or with purchase.